PPRC pipe pressure ratings explained: PN10, PN16, PN20 and PN25

Published: · BR BORLINE

Buyers often order “PN20 for everything” or “PN10 because it is cheaper”. Both can be wrong. Here is how the ratings work and how to choose.

PN and SDR

PN (nominal pressure) is the pipe’s pressure class in bar at 20 °C. For PPRC it is tied to the wall thickness, expressed as SDR — the outside diameter divided by the wall thickness. In our catalogue the plain pipes are PN10 = SDR 11, PN16 = SDR 7.4 and PN20 = SDR 6: the lower the SDR, the thicker the wall.

Temperature changes everything

PPRC is a thermoplastic; its long-term strength falls as temperature rises. DIN 8077 therefore lists an allowable operating pressure for each combination of temperature and service life. With a safety factor of 1.5:

Permissible operating pressure (bar) for PPRC pipes per DIN 8077, safety factor 1.5 — extract
Water temperatureService lifePN10 · SDR 11PN16 · SDR 7.4PN20 · SDR 6
20 °C50 years12.920.425.7
40 °C50 years9.214.518.3
60 °C50 years6.410.212.9
70 °C50 years4.26.78.5
80 °C10 years4.06.48.1

Two practical conclusions follow. First, a PN10 pipe that is perfectly adequate for a 6-bar cold-water network (12.9 bar allowed at 20 °C for 50 years) is not suitable for continuous 70 °C hot water (4.2 bar). Second, even a PN20 pipe is limited to 8.5 bar at 70 °C over 50 years — so hot-water lines on high-pressure systems need a pressure check, not just a thick pipe.

Composite and PN25 pipes

Glass-fibre composite PPRC pipes (we list PN20 and PN25) add a reinforcing layer. Their main practical advantage is lower thermal elongation: our catalogue gives 0.4 mm per 10 m per °C for the composite pipe versus 1.5 mm for plain PPRC. Pressure ratings for composite pipes should be taken from the manufacturer’s own data, not from the plain-pipe table above.

A simple selection rule

See our PPRC pipe range for available diameters per class.

Frequently asked questions

Is PN20 always better than PN16?

It has a thicker wall and a higher allowable pressure at every temperature, but it costs more and has a smaller inner diameter. For cold-water lines PN16 or PN10 is usually enough.

Sources

  1. DIN 8077 permissible operating pressure table for PPRC pipes, safety factor 1.5 (as published by SPK Boru) — https://www.spk.com.tr/en/Article/38663
  2. BR BORLINE PPRC Pipes & Fittings catalogue, October 2026 (product codes, sizes, pack quantities, technical data, welding table) — https://erp.brborline.com/kataloglar
  3. ISO 15874-2:2013 Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 2: Pipes — https://www.iso.org/standard/54155.html
Get a quote / proformaOnline catalogue+90 554 843 46 56info@brborline.com